Performance

System performance

Number of zones 0 to 4 detection zones
0 to 4 extinguishing zones
up to 4 separate discharges per zone
Maximum number of components 99
Explosion detection

Response time less than 3ms

  • fuel tank explosions
  • armour penetrations by anti-tank ammunition
Fire detection

Response time a few seconds

  • slow-growth fires
Explosion suppression Developing explosion suppressed in less than 120ms
Fire extinguishing Slow-growth fire extinguished in a few seconds
Discharge time can be extended to maintain the agent concentration (e.g. engine compartment fires)

Download Comparison chart (pdf)

Electrical performance

Operating voltage 15 to 40VDC, 28VDC nominal, MIL-STD-1275B
Current consumption Standby: 150mA (typical)
Quiescent: 40mA (typical)
Alarm: 2.5A (max.)
Fuse 3.15A
Electrical input protection MIL-STD-1275B
ISO 7637-2, 24V, class A, level IV
EMC MIL-STD-461E, Ground, Army
ESD immunity EN 61000-4-2 (ESD immunity, test level 4)
EFT immunity EN 61000-4-4 (Electrical fast transients, test level 3)

Download Comparison chart (pdf)

Environmental performance

Operating temperature -46C to +49C (STANAG 2895 C2 to A1)
Components tested: -46C to +70C
Sinusoidal vibration 1.5G, 5-500Hz, IEC 60068-2-6 test Fc (X,Y,Z)
Shock 10G, IEC 60068-2-27, 11ms
Ingress Protection IP65

Download Comparison chart (pdf)

Addressable ExAct Titan loop

  • CAN protocol 125kBps with ISO 11898-2 interface.
  • Stabilised 25V / 1A power supply, with UPS.
  • Fault tolerant with short-circuit isolators.
  • Cable connectors: 2 M12 female 5-pole.

Download Comparison chart (pdf)